Abstract
The successful implementation of H&N IMRT requires accurate and reproducible treatment delivery over a 6- to 7-week treatment course. The adverse impact of daily setup variation, which occurs routinely with conventional H&N masking techniques, may be considerably greater than recognized. Isocenter verification checks on two-dimensional orthogonal films may not sufficiently alert the clinician to the magnitude of three-dimensional offset vectors and the resultant impact on the quality of overall IMRT delivery. Unrecognized geographic miss and resultant target underdose may occur. Similarly, selected normal structures such as parotid glands may receive higher doses than intended. The results of this study suggest that more rigorous immobilization techniques than conventional masking and routine patient setup tracking methodologies are important for the accurate monitoring and successful delivery of high-quality IMRT for H&N cancer.