The detection threshold of poly(allyl dyglycol carbonate), PADC, for C ions is determined as 55 eV/nm in stopping power, which is significantly higher than that for proton and He ions. The stopping power is not a universal parameter for expressing the detection threshold of PADC. A new physical parameter of Radial Electron Fluence around Ion Tracks, REFIT, is proposed to describe the detection threshold of PADC. It is defined as the number density of electrons passing through the surface of a cylinder of a certain radius that is co-axial with the trajectory. Furthermore, preliminary calculations are presently being performed using the Monte Carlo simulation code of Geant4-DNA. The values of the REFIT at the detection thresholds for each ion are of the same order. Several issues affecting implementation of the REFIT paramter are discussed. These include the effects of impact parameter relating to the initial locations of secondary electrons, the effects of electron attachment below the cut off energy of 7.4 eV and the necessity of a more physically realistic medium than water for Monte Carlo simultaions.