Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10127276 | Applied Thermal Engineering | 2018 | 39 Pages |
Abstract
Flow filed and thermal performance of tri-lobed tube with twisted tape is investigated in this work. This investigation has been performed at different Reynolds number from 5000 to 20,000 for various pitches of 100, 150 and 200â¯mm. Because of geometric parameters effect in flow filed and heat transfer, investigations have been done by four different ratios of baffle width to tube diameter (W/Dâ¯=â¯0.15, 0.25, 0.34 and 0.4). Numerical results showed that by increasing the Reynolds number Nusselt number increased in all different pitches. Moreover, friction factor decreased by increasing Reynolds number. Overall thermal performance also totally decreased by increasing Reynolds number. As pitch ratio grows from 0.15 to 0.4 Nusselt number, friction factor and overall thermal performance increased. Pitches of 0.15, 0.25 and 0.34 have relatively same overall thermal performance at 20,000 Reynolds number.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
Mohammad Hemmat Esfe, Hossein Mazaheri, Sayed Sajad Mirzaei, Ehsan Kashi, Mehrdad Kazemi, Masoud Afrand,