Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10131409 | Applied Energy | 2018 | 13 Pages |
Abstract
Test results in realistic conditions showed an average 356â¯W heating power with an air temperature elevation of +6.0â¯K, while desorption cooling power was 278â¯W with an average 4.5â¯K temperature decrease. The usable energy density with this 0.163â¯m3 uninsulated reactor was 200.4â¯Wâ¯h per kg of 9% hydrated solid composite, which is adapted to seasonal storage since it is close to the 207.8â¯Wâ¯h per kg theoretical target. Electrical consumption for air circulation is only about 10â¯W, but vibration accounts for almost 70â¯W, which still needs to be reduced. Detailed results showed that a continuous solid flow and a counter current configuration would lead to further increase average outlet temperature.
Related Topics
Physical Sciences and Engineering
Energy
Energy Engineering and Power Technology
Authors
Joël Wyttenbach, Jacques Bougard, Gilbert Descy, Oleksandr Skrylnyk, Emilie Courbon, Marc Frère, Fabien Bruyat,