Article ID Journal Published Year Pages File Type
10344597 Computer Methods and Programs in Biomedicine 2012 11 Pages PDF
Abstract
The present research investigates the relationship between the central corneal thickness (CCT), Heidelberg Retina Tomograph II (HRTII) structural measurements and intraocular pressure (IOP) using an innovative non-linear multivariable regression method in order to define the risk factors in future glaucoma development and patient management. The method is implemented to data from ninety-three open angle glaucoma eyes. The results show that in established glaucoma, CCT is significantly associated with HRTII structural measurements (maximum contour depression, cup volume inferotemporally) and IOP. They are also compared to those obtained from the application of standard linear regression methods, improving the coefficient determination R2 by 35%, exhibiting thus the performance of the proposed methodology.