Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10370152 | Mechanical Systems and Signal Processing | 2005 | 18 Pages |
Abstract
This paper presents a new method based on the Sherman-Morrison identity for the elimination of mass loading effects of transducers from measured FRFs. The formulation presented here is general in the sense that it can be applied for both fixed- and moving-transducer cases. In the case of moving-transducer type of tests, the use of dummy mass is utilised. However, one of the distinct features of the new method is that it avoids the need for the measurement of cross FRFs of a structure with a dummy mass attached to the structure, hence avoiding further contamination of cross FRFs. The applicability of the method is also assessed using experimental as well as simulated data.
Related Topics
Physical Sciences and Engineering
Computer Science
Signal Processing
Authors
O Cakar, K.Y Sanliturk,