Abstract
A method for speciation, preconcentration and separation of Fe2+ and Fe3+ in different matrices was developed using solvent extraction and flame atomic absorption spectrometry. PAN as complexing reagent for Fe2+ and chloroform as organic solvent were used. The complex of Fe2+-PAN was extracted into chloroform phase in the pH range of 0.75-4.0 and Fe3+ remains in water phase in the pH range 0.75-1.25. The optimum conditions for maximum recovery of Fe2+ and minimum recovery of Fe3+ were determined as pH = 1, the stirring time of 20Â min, the PAN amount of 0.5Â mg and chloroform volume of 8Â mL. The developed method was applied to the determination of Fe2+ and Fe3+ in tea infusion, fruit juice, cola and pekmez. It is seen that there is high bioavailable iron (Fe2+) in pekmez. The developed method is sensitive, simple and need the shorter time in comparison with other similar studies.
Keywords
Related Topics
Physical Sciences and Engineering
Chemistry
Analytical Chemistry
Authors
Mehmet Yaman, Gokçe Kaya,