Simultaneous optimization of separation quality and analysis time of the micellar liquid chromatography of nine chlorophenol isomers was investigated. The effect on retention of three experimental parameters was studied using multivariate analysis. The factors studied were the concentration of sodium dodecyl sulfate, propanol content and pH of the mobile phase. The experiments were performed according to the face-centred cube central composite design and the inverse form of the experimental retention times for analytes were fitted to the polynomial models. The results of the analysis of variance showed that the models obtained explain greater than 99% of the variance observed in the chromatograms. Good predictive ability of the models was verified as high values of the statistics R2 and F were obtained for the linear relationship between predicted cross-validated and experimental values of the dependent variable. The study showed that the use of Pareto-optimality method, an approach from multi-criteria decision-making, allows the selection of the best possible combinations of separation and analysis time in micellar liquid chromatography of chlorophenols.
Keywords
Related Topics
Physical Sciences and Engineering
Chemistry
Analytical Chemistry
Authors
F. Safa, M.R. Hadjmohammadi,