Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10712780 | Magnetic Resonance Imaging | 2011 | 10 Pages |
Abstract
Since there is no algorithm to solve the Schatten p-norm minimization problem, we derive an efficient first-order algorithm. Experiments on MR brain scans show that the reconstruction and denoising accuracy from our method is at par with that of CS-based methods. Our proposed method is considerably faster than CS-based methods.
Keywords
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Condensed Matter Physics
Authors
Angshul Majumdar, Rabab K. Ward,