Article ID Journal Published Year Pages File Type
10732192 Radiation Physics and Chemistry 2005 11 Pages PDF
Abstract
The X-ray linear attenuation coefficient was measured for materials containing elements hydrogen to calcium. Characteristic X-rays with energies 32-66keV were produced by X-ray fluorescence using a secondary target system, and 140keV gamma rays were obtained from an unsealed 99mTc source. The photon beams were highly collimated and recorded using energy dispersive detection. A high-purity germanium detector was utilised to distinguish between measurements with Kα and Kβ characteristic X-rays, and the gamma ray measurements used a sodium iodide detector. Samples were selected on the basis of having known composition and mass densities were measured using a pycnometer. The samples comprised six plastics, seven crystalline materials, three tissue substitute materials, three liquids and six salt solutions. Our results have an uncertainty of less than 2% and are a few percent lower than values predicted by the tabulations.
Keywords
Related Topics
Physical Sciences and Engineering Physics and Astronomy Radiation
Authors
,