Article ID Journal Published Year Pages File Type
1082379 Journal of Clinical Epidemiology 2012 7 Pages PDF
Abstract

ObjectiveStudies measuring interobserver agreement (reliability) are common in clinical practice, yet discussion of appropriate sample size estimation techniques is minimal as compared with clinical trials. The authors propose a sample size estimation technique to achieve a prespecified lower and upper limit for a confidence interval for the κ coefficient in studies of interobserver agreement.Study Design and SettingThe proposed technique can be used to design a study measuring interobserver agreement with any number of outcomes and any number of raters. Potential application areas include: pathology, psychiatry, dentistry, and physical therapy.ResultsThis technique is illustrated using two examples. The first considers a pilot study in oral radiology, whose authors studied the reliability of the mandibular cortical index as measured by three dental professionals. The second example examines the level of interobserver agreement among four nurses with respect to five triage levels used in the Canadian Triage and Acuity Scale.ConclusionThis method should be useful in the planning stages of an interobserver agreement study in which the investigator would like to obtain a prespecified level of precision in the estimation of κ. An R software package (R Foundation for Statistical Computing, Vienna, Austria), kappaSize is also provided that implements this method.

Related Topics
Health Sciences Medicine and Dentistry Public Health and Health Policy
Authors
, ,