Abstract
Mixed-level designs have become widely used in the practical experiments. When the levels of some factors are difficult to be changed or controlled, fractional factorial split-plot (FFSP) designs are often used. It is highly to know when a mixed-level FFSP design with resolution III or IV has clear effects. This paper investigates the conditions of a resolution III or IV FFSP design with both two-level and four-level factors to have various clear factorial effects, including two types of main effects and three types of two-factor interaction components. The structures of such designs are shown and illustrated with examples.
Keywords
Related Topics
Physical Sciences and Engineering
Mathematics
Applied Mathematics
Authors
Shengli Zhao, Xiangfei Chen,