| Article ID | Journal | Published Year | Pages | File Type |
|---|---|---|---|---|
| 1164942 | Analytica Chimica Acta | 2013 | 7 Pages |
•Pa(V) and Np(V) behaviour in HCl and HNO3 with AG1-X8, TEVA, TRU and U/TEVA resins.•Efficient separation of Pa from Np.•Efficient separation of Pa from uranium matrix material.
Literature data on distribution ratios (Dw) of Np(V) and Pa(V) for the AG1-X8 resin are scarce whereas those related on resin capacity factors (k′) values for TEVA, TRU and U/TEVA resins are absent. Therefore, batch extraction experiments for Pa(V) and Np(V) from HCl and HNO3 media were realized, at tracer scale, with AG1-X8 and EIChroM resins (TEVA, TRU and U/TEVA). Based on the new Dw and k′ values obtained in this study, a new protocol for Pa/Np separation has been developed leading to a better separation factor of 105 and a chemical yield of 97 ± 3% and 99 ± 1% for Pa and Np, respectively. A separation of 231Pa from uranium matrix was successfully tested.
Graphical abstractFigure optionsDownload full-size imageDownload as PowerPoint slide