Article ID Journal Published Year Pages File Type
1165625 Analytica Chimica Acta 2013 7 Pages PDF
Abstract

A new sensor for simultaneous determination of peroxyacetic acid and hydrogen peroxide using silver nanoparticles (Ag-NPs) as a chromogenic reagent is introduced. The silver nanoparticles have the catalytic ability for the decomposition of peroxyacetic acid and hydrogen peroxide; then the decomposition of them induces the degradation of silver nanoparticles. Hence, a remarkable change in the localized surface plasmon resonance absorbance strength could be observed. Spectra-kinetic approach and artificial neural network was applied for the simultaneous determination of peroxyacetic acid and hydrogen peroxide. Linear calibration graphs were obtained in the concentration range of (8.20 × 10−5 to 2.00 × 10−3 mol L−1) for peroxyacetic acid and (2.00 × 10−5 to 4.80 × 10−3 mol L−1) for hydrogen peroxide. The analytical performance of this sensor has been evaluated for the detection of simultaneous determination of peroxyacetic acid and hydrogen peroxide in real samples.

Graphical abstract.Figure optionsDownload full-size imageDownload as PowerPoint slideHighlights► A sensor for determination of peroxyacetic acid and hydrogen peroxide is introduced. ► Sol–gel silica thin film containing Ag-NPs was synthesized as a sensor membrane. ► Change in the localized surface plasmon resonance intensity of Ag-NPs was observed. ► The analytical performance of this sensor has been evaluated in disinfectant solutions.

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , , ,