Article ID Journal Published Year Pages File Type
1166772 Analytica Chimica Acta 2012 7 Pages PDF
Abstract

Cd(II) imprinted 3-mercaptopropyltrimethoxysilane (MPTS)-silica coated stir bar was prepared by sol–gel technique combining with a double-imprinting concept for the first time and was employed for stir bar sorptive extraction (SBSE) of trace Cd(II) from water samples followed by inductively coupled plasma mass spectrometry (ICP-MS) detection. A tetramethoxysilane (TMOS) coating was first in situ created on the glass bar surface. Afterward, a sol solution containing MPTS as the functional precursor, ethanol as the solvent and both Cd(II) and surfactant micelles (cetyltrimethylammonium bromide, CTAB) as the template was again coated on the TMOS bar. The structures of the stir bar coating were characterized by FT-IR spectroscopy. Round-bottom vial was used for the extraction of Cd(II) by SBSE to avoid abrasion of stir bar coatings. The factors affecting the extraction of Cd(II) by SBSE such as pH, stirring rate and time, sample/elution volume and interfering ions have been investigated in detail, and the optimized experimental parameters were obtained. Under the optimized conditions, the adsorption capacities of non-imprinted and imprinted coating stir bars were found to be 0.5 μg and 0.8 μg bar−1. The detection limit (3σ) based on three times standard deviations of the method blanks by 7 replicates was 4.40 ng L−1 and the relative standard deviation (RSD) was 3.38% (c = 1 μg L−1, n = 7). The proposed method was successfully applied for the analysis of trace Cd(II) in rain water, East Lake and Yangtze River water. To validate the proposed method, certified reference material of GSBZ 50009-88 environmental water was analyzed and the determined value is in a good agreement with the certified value. The developed method is rapid, selective, sensitive and applicable for the analysis of trace Cd(II) in environmental water samples.

Graphical abstractIon imprinted 3-mercaptopropyltrimethoxysilane (MPTS) coated stir bar for selective extraction of trace Cd(II).Figure optionsDownload full-size imageDownload as PowerPoint slideHighlights► Ion imprinted polymers were proposed as the coating for SBSE for the first time. ► Cd(II) imprinted MPTS-silica coating was prepared by a double-imprinting concept. ► A novel method of SBSE–ICP-MS was developed for the determination of Cd in waters. ► This method is rapid, selective, sensitive and applicable for determining trace Cd(II) in waters.

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, ,