Article ID Journal Published Year Pages File Type
1167734 Analytica Chimica Acta 2010 7 Pages PDF
Abstract

Voltammetric investigation of two corticoid isomers—testosterone and epitestosterone has been carried out at bare and single-wall carbon nanotubes (SWNT)-modified edge plane pyrolytic graphite electrode (EPPGE). Square wave voltammetry (OSWV) has been used for the simultaneous determination of isomeric steroids. The reduction of the two isomers occurred in a pH dependent, 2e, 2H+ process and well-defined voltammetric peaks were observed. Under the optimum experimental conditions, linear calibration curves are obtained within the concentration range 5–1000 nM for both the steroids with the limit of detection 2.8 × 10−9 and 4.1 × 10−9 M for testosterone and epitestosterone respectively. The developed protocol is successfully implemented for the analysis of both the compounds in the urine samples of normal subjects as well as in patients undergoing treatment with testosterone. The results obtained from the proposed voltammetric method were also compared with HPLC analysis and found to be similar.

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , ,