Article ID Journal Published Year Pages File Type
1170309 Analytica Chimica Acta 2007 9 Pages PDF
Abstract

Mercury-pyrrolidinedithiocarbamate complexes are first time used for speciation of aquatic mercury with high-performance liquid chromatographic/ion trap-mass spectrometric method utilizing atmospheric pressure chemical ionization (APCI). The separation of the four mercury species was achieved in less than 5 min with a linear gradient profile of aqueous methanol from 70 up to 100% (v/v) in 4th min, isocratic elution at 100% up to 5th min and followed by a negative gradient to 70% in 6th min. The best separation was achieved on a reverse phase Zorbax Eclipse XDB C18 column (50 mm × 2.1 mm i.d., 1.8 μm particle size). The on-column limits of detection (injection volume 1 μL) were 370 pg for methylmercury (MeHg+), 280 pg for ethylmercury (EtHg+), 250 pg for phenylmercury (PhHg+) and 90 pg for inorganic mercury (Hg2+) when the data were collected in selective ion monitoring (SIM) mode. A method of isolation and preconcentration of the mercury species using a “home-made” C18 solid phase extraction (SPE) microcolumns was developed to enhance sensitivity of the method. The preconcentration factor as much as 2500 was achieved with on-column complex formation of mercury-pyrrolidinedithiocarbamate. Methanol (100%) was chosen for elution of preconcentrated mercury species. The method was applied for the determination of mercury species in river water samples.

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , ,