Article ID Journal Published Year Pages File Type
1172436 Analytica Chimica Acta 2006 5 Pages PDF
Abstract

A rapid and sensitive screening qualitative method using a surface plasmon resonance (SPR) biosensor was developed which can detect of all fenicol antibiotic residues in shrimps from a single sample extract. This method requires ethyl acetate extraction followed by a single wash with isooctane/chloroform. Each sample extract is injected over the surfaces of two biosensor chip flow cells, one surface having the capability to detect florefenicol amine (FF amine), florefenicol (FF), and thiamphenicol (TAP) and the second surface for chloramphenicol (CAP) detection. The estimated detection capabilities (CCβ) were 0.1, 0.2, 250, and 0.5 ppb for CAP, FF, FF amine, and TAP, respectively. This quick, simple test allowed the detection of CAP residues in shrimps at the minimum required performance limit (MRPL) of 0.1 μg kg−1 for this compound and of FF, FF amine, and TAP below their maximum residue limits (MRLs).

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry