Article ID Journal Published Year Pages File Type
1277632 International Journal of Hydrogen Energy 2009 6 Pages PDF
Abstract

This paper proposes an early detection scheme of anode flooding in a PEM fuel cell. Through experimental testing of an eight-cell hydrogen-fueled polymer electrolyte stack it is shown that anode flooding can be detected prior to a rapid voltage decline. The proposed detection scheme requires no additional costly instrumentation and uses the existing voltage scan cards.The proposed scheme requires that when the fuel cell is operating at low current densities, the current load is periodically spiked to a value of at least 0.5 A/cm2. During the spike the differences between the median cell voltage and the individual cells' voltages are measured. If one or more cells significantly differ from the median anode flooding is suspected and corrective measures can be taken. Monitoring cell voltages at low current densities without spiking the load will not allow early detection of flooding. The proposed scheme is a simple, inexpensive method to lengthen the life of a fuel cell system.

Related Topics
Physical Sciences and Engineering Chemistry Electrochemistry
Authors
, , ,