Article ID Journal Published Year Pages File Type
1280370 International Journal of Hydrogen Energy 2007 6 Pages PDF
Abstract

Refrigerating experiments of metal hydride heat pump were conducted under three operating temperatures. The high pressure reaction bed is filled with LaNi4.61Mn0.26Al0.13LaNi4.61Mn0.26Al0.13, while the low pressure reactor is filled with La0.6Y0.4Ni4.8Mn0.2La0.6Y0.4Ni4.8Mn0.2. The results show that there are four processes for high-pressure reaction bed, and three processes for low-pressure reaction bed. The lowest refrigerating temperatures at the three operating temperatures are 6.5, 2.5, and 1.9∘C, respectively. Cooling power output cannot be kept constant and becomes smaller as the refrigerating process goes on. As ThTh increases, the refrigeration cycle time, temperature and pressure of high reaction beds all climb and COP and cooling power output keep increasing. There is a great deviation between the static van’t Hoff plots and the actual dynamic lnP–1000/T relations under the operating temperature of Th/Tm/Tl=150∘C/30–32∘C/20∘C.