Article ID Journal Published Year Pages File Type
1484330 Journal of Non-Crystalline Solids 2008 6 Pages PDF
Abstract

The Young’s moduli of a set of silica aerogels have been measured by two techniques: 3-point bending and uniaxial compression. The data found by the two methods differ strongly. The uniaxial compression test gives generally underestimated values of Young’s modulus, because of geometrical effects. The appropriate gauge lengths were estimated based on the discussion of Euler buckling and nonuniform stress distribution. The measured compressive moduli were analyzed to correct for machine compliance and possible misalignment under compression of the aerogels. Similarly, moduli obtained by 3-point bending depend on the length/thickness ratio of the sample, reaching equilibrium only for ratios above about 10. The corrected compressive moduli were comparable to those measured by 3-point bending on samples of sufficient length.

Keywords
Related Topics
Physical Sciences and Engineering Materials Science Ceramics and Composites
Authors
, , , ,