Article ID Journal Published Year Pages File Type
1565682 Journal of Nuclear Materials 2013 7 Pages PDF
Abstract

Doppler broadening of annihilation gamma-line combined with a slow positron beam was used to measure the momentum density distribution of annihilating pair in a set of sintered UO2 samples. The influence of surface polishing, of implantation with 800-keV 136Xe2+ at fluences of 1 × 1015 and 1 × 1016 Xe cm−2, and of annealing were studied by following the changes of the momentum distribution shape by means of S and W parameters. The program used for this purpose was VEPFIT. At the two fluences in the stoichiometric as-implanted UO2, formation of Xe bubbles was not detected. The post-implantation annealing and over-stoichiometry in the as-implanted sample caused Xe precipitation and formation of Xe bubbles.

Related Topics
Physical Sciences and Engineering Energy Nuclear Energy and Engineering
Authors
, , , , , , , ,