Abstract
Doppler broadening of annihilation gamma-line combined with a slow positron beam was used to measure the momentum density distribution of annihilating pair in a set of sintered UO2 samples. The influence of surface polishing, of implantation with 800-keV 136Xe2+ at fluences of 1 × 1015 and 1 × 1016 Xe cm−2, and of annealing were studied by following the changes of the momentum distribution shape by means of S and W parameters. The program used for this purpose was VEPFIT. At the two fluences in the stoichiometric as-implanted UO2, formation of Xe bubbles was not detected. The post-implantation annealing and over-stoichiometry in the as-implanted sample caused Xe precipitation and formation of Xe bubbles.
Related Topics
Physical Sciences and Engineering
Energy
Nuclear Energy and Engineering
Authors
Nikolay Djourelov, Benoît Marchand, Hristo Marinov, Nathalie Moncoffre, Yves Pipon, Patrick Nédélec, Nelly Toulhoat, Daniel Sillou,