Article ID Journal Published Year Pages File Type
1565888 Journal of Nuclear Materials 2013 6 Pages PDF
Abstract

The effects of specimen size on the compressive strength and Weibull modulus were investigated for nuclear graphite of different coke particle sizes: IG-110 and NBG-18 (average coke particle size for IG-110: 25 μm, NBG-18: 300 μm). Two types of cylindrical specimens, i.e., where the diameter to length ratio was 1:2 (ASTM C 695-91 type specimen, 1:2 specimen) or 1:1 (1:1 specimen), were prepared for six diameters (3, 4, 5, 10, 15, and 20 mm) and tested at room temperature (compressive strain rate: 2.08 × 10−4 s−1). Anisotropy was considered during specimen preparation for NBG-18. The results showed that the effects of specimen size appeared negligible for the compressive strength, but grade-dependent for the Weibull modulus. In view of specimen miniaturization, deviations from the ASTM C 695-91 specimen size requirements require an investigation into the effects of size for the grade of graphite of interest, and the specimen size effects should be considered for Weibull modulus determination.

Related Topics
Physical Sciences and Engineering Energy Nuclear Energy and Engineering
Authors
,