Article ID Journal Published Year Pages File Type
1566891 Journal of Nuclear Materials 2011 4 Pages PDF
Abstract

The enthalpy increments of PuPO4 have been measured using drop calorimetry in the temperature range from 530 K to 1386 K. The heat capacity was derived from the obtained data and compared with heat capacity data obtained directly from differential scanning calorimeter measured in this study from 400 K to 1400 K. The recommended heat capacity of PuPO4 was determined based on both techniques as:Cp0(JK-1mol-1)=126.600+32.999×10-3(T/K)-1.9503×106(T/K)-2.

► The heat capacity of PuPO4 has been measured up to 1400 K. ► Good agreement between the DSC and the drop technique has been found. ► It was demonstrated that drop calorimetry is precise enough to measure relatively small samples.

Related Topics
Physical Sciences and Engineering Energy Nuclear Energy and Engineering