Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1567095 | Journal of Nuclear Materials | 2011 | 7 Pages |
Abstract
The ACO-3 irradiation test, which attained extremely high burnups of about 232Â GWd/t and resisted a high neutron fluence (EÂ >Â 0.1Â MeV) of about 39Â ÃÂ 1026Â n/m2 as one of the lead tests of the Core Demonstration Experiment in the Fast Flux Test Facility, demonstrated that the fuel pin cladding made of ferritic/martensitic HT-9 alloy had superior void swelling resistance. The measured diameter profiles of the irradiated ACO-3 fuel pins showed axially extensive incremental strain in the MOX fuel column region and localized incremental strain near the interfaces between the MOX fuel and upper blanket columns. These incremental strains were as low as 1.5% despite the extremely high level of the fast neutron fluence. Evaluation of the pin diametral strain indicated that the incremental strain in the MOX fuel column region was substantially due to cladding void swelling and irradiation creep caused by internal fission gas pressure, while the localized strain near the MOX fuel/upper blanket interface was likely the result of the pellet/cladding mechanical interaction (PCMI) caused by cesium/fuel reactions. The evaluation also suggested that the PCMI was effectively mitigated by a large gap size between the cladding and blanket column.
Related Topics
Physical Sciences and Engineering
Energy
Nuclear Energy and Engineering
Authors
Tomoyuki Uwaba, Masahiro Ito, Tomoyasu Mizuno, Kozo Katsuyama, Bruce J. Makenas, David W. Wootan, Jon Carmack,