Article ID Journal Published Year Pages File Type
1569714 Journal of Nuclear Materials 2006 8 Pages PDF
Abstract
Helium implanted uranium dioxide sintered samples were studied using nuclear reaction analysis prior to and following heavy ion irradiations and temperature anneals at 800 °C and 1100 °C. The results show that the heavy ion irradiations do not produce measurable long range movement of helium atoms. However, the ion irradiations do affect the behaviour of helium during subsequent temperature anneals. As regards the 800 °C anneal, the reduced mobility of helium in the ion-irradiated samples is interpreted as resulting from enhanced helium atom segregation produced by the ion-irradiation. Conversely at 1100 °C, the initial heavy ion irradiation appears to produce a greater than expected movement of helium within the bulk of the sample which could be an indication of defect assisted helium diffusion. Thermal diffusion coefficients are also reported at 800 °C and 1100 °C based on an analysis using a one-dimensional diffusion model.
Related Topics
Physical Sciences and Engineering Energy Nuclear Energy and Engineering
Authors
, , , , , , , ,