Article ID Journal Published Year Pages File Type
1807411 Magnetic Resonance Imaging 2008 8 Pages PDF
Abstract

Interventions for peripheral arterial disease should be designed to treat a physiological rather than an anatomic defect. Thus, for vascular surgeons, functional information about stenoses is as important as the anatomic one. In case of finding a stenosis by the use of magnetic resonance angiography, it would be a matter of particular interest to derive automatically and directly objective information about the hemodynamic influence on blood flow, caused by patient-specific stenoses. We developed a methodology to noninvasively perform numerical simulations of a patient's hemodynamic state on the basis of magnetic resonance images and by the means of the finite element method. We performed patient-specific three-dimensional simulation studies of the increase in systolic blood flow velocity due to stenoses using the commercial computational fluid dynamic software package FIDAP 8.52. The generation of a mesh defining the flow domain with a stenosis and some simulation results are shown.

Related Topics
Physical Sciences and Engineering Physics and Astronomy Condensed Matter Physics
Authors
, , , , , , ,