Article ID Journal Published Year Pages File Type
1836724 Nuclear Physics A 2016 11 Pages PDF
Abstract

We establish the equivalence of the various techniques for measuring B(E2) values using a statistical analysis. Data used in this work come from the recent compilation by B. Pritychenko et al. (2016) [5]. We consider only those nuclei for which the B(E2) values were measured by at least two different methods, with each method being independently performed at least twice. Our results indicate that most prevalent methods of measuring B(E2) values are equivalent, with some weak evidence that Doppler-shift attenuation method (DSAM) measurements may differ from Coulomb excitation (CE) and nuclear resonance fluorescence (NRF) measurements. However, such an evidence appears to arise from discrepant DSAM measurements of the lifetimes for 60Ni and some Sn nuclei rather than a systematic deviation in the method itself.

Related Topics
Physical Sciences and Engineering Physics and Astronomy Nuclear and High Energy Physics