Article ID Journal Published Year Pages File Type
1847930 Nuclear Science and Techniques 2008 5 Pages PDF
Abstract
The performance of a compact position sensitive gamma-ray detector based on wavelength-shifting fibers coupled to YAIO3:Ce scintillation crystal was evaluated using a Monte-Carlo simulation method. The simulation model has been setup using the GEANT4 codes. Compared with the gamma-ray detector based on the YAIO3:Ce scintillation crystal coupled to Hamamastu R2486 position sensitive photomultiplier tube, the results indicate that the gamma-ray detector based on wavelength-shifting fibers readout has good position linearity, good spatial resolution and larger effective field of view. The image and point spread function of measured point were presented. The spatial resolution response as a function of position was obtained. The factors influencing spatial resolution and position linearity were discussed.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Nuclear and High Energy Physics