Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1848468 | Nuclear Science and Techniques | 2007 | 4 Pages |
Abstract
Cadmium zinc telluride (CZT) is a preferred material for X-ray and gamma-ray detector. Thanks to the relatively high atomic number, high density and wide band-gap, CZT detector possesses sharp energy resolution and high detection efficiency without cryogenic cooling. We have developed a CdZnTe detector with an energy resolution of 3.45% (FWHM) at 59.54 keV at room temperature, and it is used for X-ray fluorescence analysis. In this paper, leakage current, energy resolution and long term stability of the CZT detector are discussed.
Keywords
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Nuclear and High Energy Physics
Authors
XU Huichao, CHENG Cheng, ZHAO Cuilan, ZHANG Jinzhou, PU Shijie,