Abstract
The goal of the MRPC–detector production for the ALICE TOF is to guarantee the same excellent performances obtained so far with all the prototypes. A set of quality assurance tests has been developed for this purpose; these tests are applied both to the single chamber components and to the assembled detectors. In this paper the results of these tests over a few hundreds MRPCs of the mass production will be presented.