Abstract
A test device for isotopic γ-ray imaging, which consists of an isotope γ-ray source, a CdZnTe γ-ray spectrometer and other auxiliary equipment, is studied here. Compared with the conventional X-ray, the isotope y-ray, which is utilized in this project, has its own advantages in imaging. Furthermore, with a room-temperature high-energy-resolution CdZnTe detector and a modern imaging processing technique, this device is capable of effectively suppressing the background and gaining more information, thus it can obtain a better image than conventional X-ray devices. In the experiment of PCB imaging, all soldered points and chip components are sharply demonstrated.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Nuclear and High Energy Physics