1884002 | Radiation Physics and Chemistry | 2012 | 4 Pages |
For the identification of irradiated food, current analysis methods have limitations regarding presence and stability of radiation-induced markers. In this study, different spice blends with small quantity of different irradiated (0, 1 and 10 kGy) spice powders, such as red pepper, garlic or ginger, were investigated using PSL and TL techniques. In PSL-based screening analysis, the spice blends containing 10% of irradiated materials (1 or 10 kGy) were determined as intermediate or positive. In TL results, the blends containing 1% of 1 or 10 kGy-irradiated spices showed the typical TL glow curves that could be interpreted as positive. The blends with irradiated garlic powder provided more good results where identification was possible at 0.5% mixing of irradiated sample. However, the TL ratios of all spice blends were <0.1 and only TL glow curve shape and intensity may be used to discriminate the samples having irradiated component.
► Sample blends with small quantities of irradiated spices were evaluated. ► The PSL was inappropriate to detect irradiated ingredient in small quantity. ► TL glow curve shape and intensity could be used as conclusive evidence of irradiation. ► TL ratios of all irradiated and nonirradiated samples were <0.1.