Abstract
Multiple scattering of gamma photons obtained from 0.215 GBq 137Cs source in both forward and backward hemisphere for 4 elements viz., carbon, aluminium, iron and copper are detected by a 76 mm Ã76 mm NaI(Tl) scintillation detector. The variation of saturation thicknesses of 4 elements are studied experimentally at 60°, 80°, 90°, 100°, 120° and 135°. Monte Carlo N-Particle (MCNP) simulation of multiple scattering and variation in saturation thicknesses is carried out for 40°, 60°, 80°, 90°, 100°, 120°, 135°, 160° and 180° for four elements. The variation of the intensity of multiple scattered photons in different scattering angles is found to be different in forward and backward hemispheres. The intensity of multiple scattered photons is found to be minimum at around 90°. Saturation thicknesses for 40° and 60° are found to be less than saturation thicknesses for 80°, 90°, 100°, 120°, 135°, 160° and 180° in spite of the fact that the scattered energy is more for lower scattering angles. The behaviour of variation of saturation thicknesses as a function of scattering angles obtained from MCNP simulation agrees well with experimentally obtained values.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Radiation
Authors
K.U. Kiran, K. Ravindraswami, K.M. Eshwarappa, H.M. Somashekarappa,