Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1988427 | Journal of Biochemical and Biophysical Methods | 2008 | 7 Pages |
A simple, rapid and precise HPLC method has been developed for the assay of verapamil in human plasma. The clean up of the plasma samples was tested using several adsorbents for solid-phase extraction and best recovery was obtained using mixed-mode cartridges (HLB - hydrophilic-lipophilic balance) ranging between 94.70 and 103.71%. HPLC separation was performed with isocratic elution on Lichrospher 60 RP-select B column (250 mm × 4 mm I.D., 5 μm particle size). The mobile phase was 40% acetonitrile and 0.025 mol/L KH2PO4 with pH 2.5 at flow rate of 1 mL/min. Diltiazem was used as internal standard and the detection wavelength was 200 nm. The calibration curves were linear in the range of 10–500 ng/mL. The developed method is convenient for routine analysis of verapamil in human plasma.