Article ID Journal Published Year Pages File Type
2091146 Journal of Microbiological Methods 2006 11 Pages PDF
Abstract

A validated PCR-based Salmonella method targeting a 94-bp sequence of the ttr gene was used as a model to compare six different combinations of reporter and quencher dyes of a TaqMan probe, on three different instruments, to improve the detection limit in a real-time PCR assay with the aim of a same-day analysis. The use of locked nucleic acids (LNA) and Scorpion probes were also tested. The combination FAM–BHQ1 or Cy5–BHQ3, both dark quenchers, gave the best results (Cycle threshold (Ct) of 25.42 ± 0.65 and 24.47 ± 0.18 at 103 DNA copies). When comparing different probe technologies, the LNA probe (FAM–BHQ1) was the most sensitive with the strongest fluorescence signal (dR last 48 066), resulting in 0.6 to 1.1 lower Ct values than a DNA TaqMan probe, and 1.9 to 4.0 lower Ct than the Scorpion system (FAM–BHQ1). The RotorGene real-time PCR instrument gave 0.4–1.0 lower Ct values (more sensitive) than the Mx3005p, and 1.5–3.0 lower than the ABI 7700. Using the LNA in a RotorGene instrument, we detected the following Salmonella DNA copies in 1-ml pre-enriched samples: fishmeal (100 copies), chicken rinse (100 copies) and pig feces (10 copies). The detection probability of the final assay on inoculated fecal samples was 100% at 2 × 104 copies per ml. In conclusion, the LNA probe with annealing temperature of 65 °C could be useful for more sensitive detection limits.

Related Topics
Life Sciences Biochemistry, Genetics and Molecular Biology Biotechnology
Authors
, , , ,