The paper describes the results of stripping voltammetry usage to control concentration of lead ion which are formed during electrochemical detoxication of organic pollutants. Optimal conditions for the analysis of Pb2+ were selected, i.e. 0.05 N KOH is an electrolyte, the deposition potential (-0.55) V, deposition time of 4 minutes, the amount of analyzed sample was 0.1 ml. The presence of organic matter does not affect the quantitative determination of lead ions. The developed method allows us to estimate the concentration of Pb2+ in the amount of electrolyte at disposal of toxicants quickly and with a high degree of sensitivity.