Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
2485237 | Journal of Pharmaceutical Sciences | 2012 | 8 Pages |
Abstract
Detection and quantification of the amorphous phase of etoricoxib bulk drug substances, a selective cycloogenase-2 inhibitor used for the treatment of osteoarthritis, rheumatoid arthritis, and dental pain, was carried out using modulated differential scanning calorimetry (MDSC), dynamic mechanical analysis (DMA), and Raman spectroscopy. Detection of amorphous content in pharmaceutical powders by DMA is a special application of dynamic mechanical spectroscopy. DMA was found to be a sensitive technique, able to detect the presence of an amorphous phase in a crystalline phase at concentrations as low as 0.5%. The limit of detection (LOD) determined for DMA was 2.5%. In comparison, Raman spectroscopy and MDSC had LOD values of 2% and 5% amorphous, respectively. © 2011 Wiley Periodicals, Inc. and the American Pharmacists Association.
Keywords
Related Topics
Health Sciences
Pharmacology, Toxicology and Pharmaceutical Science
Drug Discovery
Authors
Sophie-Dorothee Clas, Karine Lalonde, Karine Khougaz, Chad R. Dalton, Rana Bilbeisi,