Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
2487275 | Journal of Pharmaceutical Sciences | 2008 | 10 Pages |
Abstract
Effects of particle size, morphology, particle density, and surface silicification, on powder flow properties were investigated using a ring shear tester. Flow properties were quantified by flow function (FF), that is, unconfined yield strength, fc, as a function of major principal stress. A total of 11 powders from three series of microcrystalline cellulose (MCC): Avicel (regular MCC, elongated particles), Prosolv (silicified MCC, elongated particles), and Celphere (spherical MCC), were studied. Particle size distribution in each type of MCC was systematically different. Within each series, smaller particles always led to poorer powder flow properties. The slope of FF line was correlated to degree of powder consolidation by external stress. A key mechanism of the detrimental effect of particle size reduction on flow properties was the larger powder specific surface area. Flow properties of Celphere were significantly better than Avicel of comparable particles size, suggesting spherical morphology promoted better powder flow properties. Flow properties of powders different in densities but similar in particle size, shape, and surface properties were similar. When corrected for density effect, higher particle density corresponded to better flow behavior. Surface silicification significantly improved flow properties of finer MCC, but did not improve those of coarser.
Keywords
Related Topics
Health Sciences
Pharmacology, Toxicology and Pharmaceutical Science
Drug Discovery
Authors
Hao Hou, Changquan Calvin Sun,