Article ID Journal Published Year Pages File Type
2507967 Journal of Pharmaceutical Analysis 2013 8 Pages PDF
Abstract

A novel, fast, sensitive and robust method based on ultra-performance liquid chromatography coupled to atmospheric pressure electrospray ionization tandem mass spectrometry (UPLC–ESI-MS/MS) has been developed to separate two Tibolone stereoisomers i.e., 3α-Hydroxy Tibolone and 3β-Hydroxy Tibolone and to quantify 3α-Hydroxy Tibolone using p-toulenesulfonyl isocyanate (PTSI) as a derivatizing reagent in human plasma. 3α-Hydroxy Tibolone-13CD3 was used as an internal standard (IS). The analyte and IS were extracted from human plasma by liquid–liquid extraction using ethyl acetate. Extracted samples were analyzed by UPLC–ESI-MS/MS. Chromatography was performed using binary gradient on UPLC analytical column. A linear calibration curve over the range of 0.100–35.000 ng/mL was obtained and lower limit of quantification (LLOQ) was 0.100 ng/mL demonstrating acceptable accuracy and precision. This method was successfully applied to a pharmacokinetic study in order to compare a test Tibolone 2.5 mg formulation vs. a reference 2.5 mg Tibolone tablet formulation in 50 post-menopausal/surgical menopause female human volunteers under fasting conditions. It is concluded that test formulation of Tibolone is bioequivalent to reference formulation of Tibolone.

Related Topics
Health Sciences Pharmacology, Toxicology and Pharmaceutical Science Pharmaceutical Science
Authors
, , , , ,