Article ID Journal Published Year Pages File Type
2638032 American Journal of Infection Control 2012 8 Pages PDF
Abstract

BackgroundIt has been shown that nontoxic concentrations of ethanol are absorbed after hand hygiene using ethanol-based hand rubs. This study investigated whether absorption of propan-1-ol and propan-2-ol from commercially available hand rubs results in measurable concentrations after use.MethodsThe pulmonary and dermal absorption of propanol during hand rubs was investigated. Rubs contained 70% (w/w) propan-1-ol, 63.14% (w/w) propan-2-ol, or 45% (w/w) propan-2-ol in combination with 30% (w/w) propan-1-ol.ResultsPeak median blood levels were 9.15 mg/L for propan-1-ol and 5.3 mg/L for propan-2-ol after hygienic hand rubs and 18.0 mg/L and 10.0 mg/L, respectively, after surgical hand rubs. Under actual surgical conditions, the highest median blood levels were 4.08 mg/L for propan-1-ol and 2.56 mg/L for propan-2-ol. The same procedure performed with prevention of pulmonary exposure through the use of a gas-tight mask resulted in peak median blood levels of 1.16 mg/L of propan-1-ol and 1.74 mg/L of propan-2-ol.ConclusionOnly minimal amounts of propanols are absorbed through the use of hand rubs. Based on our experimental data, the risk of chronic systemic toxic effects caused by hand rubs is likely negligible. However, our study did not evaluate the consequences of long-term daily and frequent use of hygienic hand rubs.

Related Topics
Life Sciences Immunology and Microbiology Microbiology
Authors
, , , , , , , , , , , , , , ,