Article ID Journal Published Year Pages File Type
2639874 American Journal of Infection Control 2010 9 Pages PDF
Abstract

BackgroundRespiratory protective devices exposed to pathogenic microorganisms present a potential source of transmission of infection during handling. In this study, the efficacy of 4 antimicrobial respirators to decontaminate MS2, a surrogate for pathogenic viruses, was evaluated and compared with control N95 filtering face piece respirators, which did not contain any known antimicrobial components.MethodsMS2 containing droplet nuclei were generated using a Collison nebulizer and loaded onto respirator coupons at a face velocity of 13.2 cm/seconds for 30 minutes. The coupons were incubated at 2 different temperature and relative humidity (RH) conditions and analyzed for viable MS2 at different time intervals.ResultsResults showed that log10 reduction of MS2 was not statistically significant (P > .05) between the control and antimicrobial respirator coupons, when stored at 22°C and 30% RH up to 20 hours. Coupons from 1 of the 4 antimicrobial respirators showed an average MS2 log10 reduction of 3.7 at 37°C and 80% RH for 4 hours, which was statistically significant (P ≤ .05) compared with coupons from the control respirators.ConclusionResults from this study suggest that MS2 virus decontamination efficacy of antimicrobial respirators is dependent on the antimicrobial agent and storage conditions.

Related Topics
Life Sciences Immunology and Microbiology Microbiology
Authors
, , ,