Article ID Journal Published Year Pages File Type
264960 Energy and Buildings 2015 7 Pages PDF
Abstract

In this paper, an attempt has been made to validate the thermal model with experimental results of a typical day August, 25, 2006 for clear weather condition of New Delhi. An energy and exergy analysis for the prediction of performance of a photovoltaic/thermal (PV/T) collector integrated with a greenhouse at I.I.T, Delhi, India has been carried out. The analysis is based on quasi-steady state condition. Experiments have been conducted extensively during period from June 2006 to May 2007, for annual performance. Numerical computation has been carried out for a typical day only for validation. It is observed that the theoretical value of solar cell, tedlar back surface and greenhouse room air temperatures is approximately equivalent to the experimental values. The predicted and measured values of solar cell, tedlar back surface and greenhouse air temperatures have been verified in terms of root mean square of percent deviation (7.05–17.58%) as well as correlation coefficient (0.95–0.97) and both exhibit fair agreement. Exergy analysis calculations of the PV/T integrated greenhouse system show an exergy efficiency level of approximately 4%.

Related Topics
Physical Sciences and Engineering Energy Renewable Energy, Sustainability and the Environment