Article ID Journal Published Year Pages File Type
2764352 Journal of Critical Care 2016 5 Pages PDF
Abstract

ObjectiveThe objective was to determine whether central-venous oxygen saturation (ScvO2 < 70%) can be detected from the difference between invasively and noninvasively measured systolic blood pressure (BP) (ie, ΔBP defined as arterial BP minus noninvasive BP).MethodsThis is a cross-sectional study at a single medical and surgical intensive care unit in Japan. All hypotensive patients admitted to intensive care unit were eligible. Arterial BP was measured via a radial-artery catheter, and noninvasive BP on the same side was measured via a brachial cuff. ScvO2 was measured by gas analysis of blood sampled from a central-venous chatheter (CVC). We calculate the area under the curve for ΔBP as an indicator of ScvO2 < 70%.ResultsUsable data were obtained from the records of 111 patients. The median and interquartile range of ΔBP and ScvO2 were − 4 mm Hg (− 11, 6) and 67% (60.9, 73.9), respectively. The area under the curve of ΔBP as an indicator of ScvO2 < 70% was 0.81 (95% confidence interval [CI], 0.73-0.89). With a cutoff ΔBP of 0, sensitivity was 65.7% (95% CI, 53.1-76.8), specificity was 97.7% (95% CI, 88.0-99.8), and positive predictive value was 97.8 (95% CI, 88.2-99.9).ConclusionsΔBP can indicate whether ScvO2 is lower than 70%. When that difference is greater than 0, ScvO2 is very likely to be lower than 70%.

Related Topics
Health Sciences Medicine and Dentistry Anesthesiology and Pain Medicine
Authors
, , , , , ,