Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
2849651 | American Heart Journal | 2010 | 6 Pages |
BackgroundCardiac troponins are currently the markers of choice for diagnosis of acute myocardial infarction and risk assessment in acute coronary syndrome (ACS). With the introduction of the new high-sensitivity cardiac troponin T (hs-cTnT) assay, it has become possible to measure cTnT even in healthy subjects. However, how the hs-cTnT assay compares with the old cTnT assay for risk assessment in ACS is still unknown.MethodsCardiac troponin T levels were measured with the new hs-cTnT assay and the old third-generation cTnT assay in serum samples collected 48 hours after randomization in 1,452 randomly selected ACS patients enrolled in the GUSTO-IV trial. During 30 days of follow-up, deaths and myocardial infarctions were recorded. At 12 months, only all-cause mortality was collected.ResultsThe 16% of the patients that had levels higher than the 99th percentile cutoff for hs-cTnT but less than for cTnT had a similar 1-year mortality as the 60% that were positive for both assays (9.2% vs 10.7%, P = .52) and a higher 1-year mortality compared with the 24% that were negative for both assays (9.2% vs 2.6%, P = .001). For death or acute myocardial infarction at 30 days, the group that was positive only for hs-cTnT had an intermediate risk compared with the groups negative or positive for both assays (2.4%, 5.2%, and 8.7%; P < .001).ConclusionThe new hs-cTnT assay, compared with the old cTnT assay, identified more patients with myocardial damage and who were at an increased risk for new cardiac events.