Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
285917 | Journal of Constructional Steel Research | 2009 | 6 Pages |
Abstract
The ultimate capacity of beams prestressed with external slipping tendons cannot be evaluated by a local analysis of the critical sections and a nonlinear analysis of the whole beam-tendon structural system is required. Since this type of analysis is complex, simplified approaches are of great assistance to engineers in the design process. In this work a new simplified method is introduced for evaluating the tendon traction increment at collapse and consequently the beam flexural strength without requiring a nonlinear analysis of the whole beam-tendon structural system. A detailed description of the proposed approach is given and some applications of practical interest to externally prestressed steel–concrete composite beams are discussed.
Keywords
Related Topics
Physical Sciences and Engineering
Engineering
Civil and Structural Engineering
Authors
Alessandro Zona, Laura Ragni, Andrea Dall’Asta,