Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
2957763 | Journal of Arrhythmia | 2013 | 4 Pages |
We describe treatment of atrial flutter and electrical storm presenting as incessant ventricular tachycardia (VT) after implantation of a cardiac resynchronization therapy defibrillator (CRT-D) in a patient with dilated cardiomyopathy. No prior arrhythmic event had occurred. Our treatment strategy, including amiodarone administration, was guided in part by signal-averaged vector-projected 187-channel electrocardiogram (SAVP-ECG)-based risk stratification for ventricular arrhythmia. Corrected recovery time (RTc) dispersion and Tpeak-end dispersion were used to evaluate transmural dispersion of repolarization. RTc and Tpeak-end dispersion increased during the period of electrical storm. Values were improved 2 years after CRT-D implantation, and the amiodarone was discontinued. The VT has not recurred despite discontinuation of the antiarrhythmic agent. SAVP-ECG-based risk stratification for ventricular arrhythmia proved useful for the management of antiarrhythmic therapy.