Article ID Journal Published Year Pages File Type
2963630 Journal of Cardiology 2009 7 Pages PDF
Abstract

SummaryBackgroundRapid and accurate methods for screening are necessary for the diagnosis of acute cardiovascular diseases (ACVD), including acute coronary syndrome (ACS), pulmonary thromboembolism, and acute aortic dissection. In this study, the utility of rapid D-dimer measurement for the screening of ACVD was evaluated.Methods and resultsConsecutive 279 emergent patients in whom ACVD was suspected or not ruled out were enrolled. The median D-dimer concentration of ACVD group (1.10 μg/ml) was significantly higher than that in the non-ACVD group (0.69 μg/ml, p < 0.05). Sensitivity, specificity, positive predictive value, and negative predictive value of D-dimer (with cut-off level of 0.75 μg/ml) for the discrimination of ACVD from non-ACVD was 75%, 55%, 38%, and 85%, respectively. In ACVD group, the level of D-dimer in the large vessel disease subgroup was significantly higher than that in the ACS subgroup (6.99 μg/ml and 0.89 μg/ml, respectively; p < 0.05). The well-balanced cut-off point for discriminating the two subgroups was D-dimer level of 5.0 μg/ml. D-dimer (with cut-off level of 0.75 μg/ml) showed significantly higher positive test rate for the detection of ACS in very early phase (within 2 h from the onset) compared with troponin T (p < 0.05).ConclusionsRapid measurement of D-dimer is useful for the screening of ACVD in the emergency setting.

Related Topics
Health Sciences Medicine and Dentistry Cardiology and Cardiovascular Medicine
Authors
, , , , , , ,