Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
3241405 | Injury | 2009 | 5 Pages |
IntroductionPFNA design compacts the cancellous bone to provide increased stability and has been bio-mechanically proven to retard rotation and varus collapse.MethodsBetween 2006 and 2007, 62 consecutive patients with unstable proximal femoral fractures were treated with the PFNA.ResultsTwenty males and 42 females with a mean age of 78 years (44–94) were reviewed. In 48 patients, the fracture resulted from a low energy injury. The majority of the fractures belonged to AO/ASIF types 31A2.3 (22) and 31A3.2 (29). Twelve patients required open reduction. The PFNA blade position was central in 52 patients with a mean tip-apex distance (TAD) of 12 mm (range 4–34 mm). Post-operatively, five patients died within 3 months and two patients were lost to follow-up. Forty-nine fractures united between 3 and 4 months. Four patients had delayed union. The PFNA blade cut out rate was 3.6%.ConclusionsUnstable proximal femoral fractures were treated successfully with the PFNA. The PFNA blade appears to provide additional anchoring in osteoporotic bone. No results have been published on this new design.