Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
3241986 | Injury | 2010 | 4 Pages |
Although there is much in the literature regarding pin site infections, there is no accepted, validated method for documenting their state. We present a system for reliably labelling pin sites on any ring fixator construct and an easy-to-remember grading system to document the state of each pin site. Each site is graded in terms of erythema, pain and discharge to give a 3-point scale, named “Good”, “Bad” and “Ugly” for ease of recall.This system was tested for intra- and inter-observer reproducibility. 15 patients undergoing elective limb reconstruction were recruited. A total of 218 pin sites were independently scored by 2 examiners. 82 were then re-examined later by the same examiners. 514 pin sites were felt to be “Good”, 80 “Bad” and 6 “Ugly”. The reproducibility of the system was found to be excellent.We feel our system gives a quick, reliable and reproducible method to monitor individual pin sites and their response to treatment.